Product Details:
Payment & Shipping Terms:
|
Model Number: | DC-A96 | Display Type: | Analog Only |
---|---|---|---|
Measuring Range: | 5A-100A | Scale: | Can Be Changeable |
Accuracy Class: | 3.0 | Frequency: | 50Hz |
High Light: | electronic watt hour meter,electronic kilowatt hour meter |
CE Approve Maximum demand Analogue Panel Meters With Accuracy Class3.0
Description :
Series Maximum Demand Ammeter is a bimetal instrument. The bimetallic movement responds and indicates the mean RMS current loading over a specified period of time. A black pointer which is attached to the bimetal spiral moves in response to the current ( heating) in the bimetal spiral. A red pointer (slave or memory pointer) is driven by the black pointer. The red pointer remains at its maximum position to which the black pointer has reached during any period of time. Further, when the loading is reduced, the red pointer remains at the maximum value. This enables the operator to know the maximum loading of the system without continuously watching the meter. A zero corrector is provided on the front of the meter to bring back the red pointer to the position of the black pointer. A sealing/locking facility is also provided on the zero corrector to prevent tampering of the reading at the red pointer.
Changeable scale plate: Draw out the dial with a suitable tool introduced in the dial perforation. When replacing the new dial, carefully close the slot of the case with the plastic cover. The dial is changeable without influence the accuracy.
The casings and frames for all instruments are made of self extinguishing ABS, according to UL94, with high impact resistance. The bases are made from self extinguishing reinforced PPO, according to UL94, with high impact resistance and maximum electrical insulation.
Due to analogue panel meter is a kind of precision measuring instrument, we strongly recommend our customers choose ocean shipping, then we can make firm wood pallet for certain cases to protect the goods against probable rough handling in the transportation.
Specification :
Model | Frame size | Mode | Measuring Range | Class Index | Case Qty. |
2 Pointers Maximum Demand Ammeter 1.2In | |||||
DT-M96 | 96X96 | x/5A T=15min | 5~6000A | 3.0 | 60Pcs |
DT-M72 | 72X72 | x/5A T=15min | 5~6000A | 3.0 | 100Pcs |
*Also T=8min or x/1A are available upon request, Special specificationos upon request.
Features :
Standards:
IEC51, IEC61010-1, VDE410, BS89, UL94, NE60051, DIN43780
Cases:
All cases at least dust and splash water-proof.
All cases are made of strengthened self-extingushing PPO With a high hit-resistance and a maximum electric isolation
Accuracy class:
AC, DC Voltmeters and Ammeters comply with the accuracy class 1.5.
The power meters comply with accuracy class 1.5.
The frequency meters comply with accuracy class1.0.
The maximum-demand meters comply with accuracy class 3.0.
The power factor meters and synchroscope meter comply with accuracy class 2.5.
Insulation test:
The insulation test is carried out at a voltage of 2KV, 50Hz 1 min and applies for instruments with the full scale deflection up to 650V. Other standards comply with IEC61010-1.
Dimension :
Frame Size | Dimension(mm) | |||||
A | B | C | D | E | F | |
96x96mm | 96 | 92 | 90 | 5.5 | 65 | 43 |
72x72mm | 72 | 68 | 66 | 5.5 | 65 | 43 |
48x48mm | 48 | 44 | 42 | 5.5 | 65 | 43 |
Contact Person: Ms. Linda
Tel: 86-577-61616258
Fax: 86-577-61616258